An uninsulated floor bleeds heat straight into the concrete slab. You'll burn far more wood, and the floor will cool after a few pizzas. Insulation under the floor is non-negotiable.
Under-floor insulation
Option A — insulation board (recommended): two layers of 2" calcium silicate or ceramic fiber board, joints staggered, laid directly on the clean, dry slab. Fast, flat and very effective.
Option B — insulating concrete: perlite or vermiculite mixed about 5:1 with portland cement and just enough water to clump. Pour 4–5" thick, screed level, and let it dry thoroughly — it holds a lot of water.
Laying the floor
- Make it dead flat. Spread a thin bed (about ¼") of dry sand mixed with fire clay over the insulation and screed it.
- Lay bricks flat, 4.5" side up, tight together with no mortar between floor bricks. Unmortared bricks can expand and be replaced individually later.
- Choose a pattern. A herringbone or diagonal pattern stops the peel catching on long joints. Straight rows work too — just run the joints front-to-back, not side-to-side.
- Tap each brick down with a rubber mallet and check with a level. Any lip will catch your peel.
- Cut the outline. Mark the dome's inside circle and either cut the floor to a circle (dome sits around it) or let the dome sit on top of the floor.
Floor sitting inside vs. under the dome
- Floor inside the dome: easier to replace a cracked floor brick later. The dome sits on the insulation layer, around the floor.
- Dome sitting on the floor: simpler layout, but the floor bricks under the dome wall are locked in.
Either works; just decide before you start the first dome course.